250 kVA 10 kV Oil-Immersed Transformer No Excitation — Fengguang Transformer 10kV Oil-Immersed Distribution Transformer

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

10kV Distribution Transformers

250 kVA 10 kV Oil-Immersed Transformer No Excitation

250 kVA 10 kV 10kV Oil-Immersed Distribution Transformer

250KVA 10KV Oil Immersed Transformer - Core Outdoor Power Distribution Equipment

Quick answer. 250 kVA 10 kV Oil-Immersed Transformer No Excitation is a 10kV Oil-Immersed Distribution Transformer rated 250 kVA at 10 kV. Typical applications include 10 kV utility distribution feeders, Industrial parks and factory substations, Commercial buildings and campuses. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
10kV Oil-Immersed Distribution Transformer
Rated capacity
250 kVA
Voltage class
10 kV
Cooling
ONAN / ONAF
Tap range
Off-circuit or on-load, project-specific
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

250KVA 10KV Oil Immersed Transformer - Core Outdoor Power Distribution Equipment

Most power distribution equipment in the industry suffers from poor voltage adaptability, high losses under load fluctuations, and is prone to insulation aging and leakage in outdoor conditions. Purchasers often face challenges such as cumbersome equipment matching, complex voltage regulation operations, and high long-term maintenance costs. This 250KVA 10KV Oil Immersed Transformer features optimized heat dissipation and sealing structures, allowing for flexible integration with High And Low Voltage Switchgear and Box Type Substations to complete power distribution layouts. Compared to Dry Type Transformers, it offers stronger outdoor tolerance and overload capacity, and is compatible with Combined Photovoltaic Substations and Electric Power Converters for voltage boosting and bucking requirements. The voltage level can be adjusted even when the equipment is not in operation, providing stable output of standard low-voltage power, reducing line losses, and extending the service life of the entire power distribution system. It is widely used in industrial parks, distributed photovoltaic power stations, and urban community power distribution scenarios.

This equipment adopts a fully sealed corrugated oil tank structure, with insulating oil isolating water vapor and dust to prevent outdoor leakage faults. The non-excitation voltage regulation structure simplifies the operation process, allowing voltage level switching without the need for professional live-line workers. Compared to dry-type equipment of the same capacity, it has higher heat dissipation efficiency, adapts to short-term overload conditions of photovoltaic power station output fluctuations, and can stably suppress power harmonics when operating in conjunction with an Electric Power Converter . The equipment can be installed independently on a pole or integrated into a Box Type Substation , achieving integrated protection, metering, and power distribution when paired with a complete High and Low Voltage Switchgear. In Combined Photovoltaic Substations, it serves as the core transformer unit, completing the high-voltage grid connection after photovoltaic DC power conversion. The entire unit strictly adheres to international Energy Efficiency standards, with low operating noise and controllable losses. Long-term use can reduce electricity costs. It is compatible with the voltage standards of multiple overseas power grids, meeting the bulk procurement needs of industrial, new energy, and civil infrastructure projects.

Installation & maintenance notes

  • Voltage adjustment must be performed with the power completely off. After switching gears, retest the DC resistance to ensure stable contact before restoring power.
  • If used with Combined Photovoltaic Substations, periodically monitor the Electric Power Converter output current to prevent long-term overload damage to the windings.

Design features

What the design is built around

Non-excitation offline voltage regulation design; voltage adjustment can be completed even during power outages, ensuring safe and simple operation, and adapting to scenarios with small grid voltage fluctuations.

The fully sealed oil-immersed structure isolates air, delaying oil aging. Outdoor installations eliminate the need for frequent insulation replacements, reducing maintenance workload.

Typical specification

Specifications to confirm on the datasheet

Product type 10kV Oil-Immersed Distribution Transformer
Rated capacity 250 kVA
Voltage class 10 kV
Cooling ONAN / ONAF
Tap range Off-circuit or on-load, project-specific
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076
Testing Routine tests plus type and special tests on request

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • 10 kV utility distribution feeders
  • Industrial parks and factory substations
  • Commercial buildings and campuses
  • Distributed PV and wind projects
  • Rural electrification and grid upgrades

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 250 kVA 10 kV Oil-Immersed Transformer No Excitation

How to select between the Oil Immersed Transformer and Dry Type Transformer ?
For outdoor, high-load fluctuation, and budget-constrained applications, prioritize the oil-immersed type. For indoor, enclosed locations with high fire safety standards, choose the dry type. Both can be used with prefabricated substations and high/low voltage switchgear.
What is the routine maintenance cycle for the equipment, and what tests are required?
Check the oil level and bushing cleanliness every six months; sample and test the insulating oil withstand voltage annually; perform winding DC resistance and insulation resistance tests every two years. Frequent core-lifting maintenance is unnecessary.
How is after-sales service guaranteed for overseas orders?
The entire unit comes with a standard warranty period, a complete English operation manual and troubleshooting guide, and remote, synchronized guidance from our technical team for installation and commissioning. Core components are kept in stock for rapid replacement.
Can it be directly installed into a Box Type Substation for complete system supply?
Customized sizes are supported, allowing integration into the substation. It can be paired with a High and Low Voltage Switchgear for integrated delivery of the entire power distribution system, suitable for pre-installed photovoltaic substation projects.