Skip to content
Fengguang Transformer

Transformer family

Large Power Transformers

110 kV and 220 kV transformers for generation, transmission and large industry.

21

Models

GB/IEC

Standards

50+

Countries

Quick answer. 110 kV and 220 kV transformers for generation, transmission and large industry. Fengguang supplies 21 published models and variants in this family, with project-specific windings, cooling, protection and finish confirmed on the approved datasheet.
6300 kVA 110KA Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
6,300 kVA

6300 kVA 110KA Oil-Immersed power Transformer

In power transmission, high-voltage and large-capacity equipment suffers from high losses and poor adaptability, which are the ind…

View model
8000 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
8,000 kVA 110 kV

8000 kVA 110 kV Oil-Immersed power Transformer

The incompatibility of high-voltage and large-capacity Power Distribution Equipment and the high operation and maintenance costs a…

View model
10000 kVA 110KA Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
10,000 kVA

10000 kVA 110KA Oil-Immersed power Transformer

The insufficient operational stability and high energy consumption of high-voltage large-capacity Power Distribution Equipment are…

View model
12500 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
12,500 kVA 110 kV

12500 kVA 110 kV Oil-Immersed power Transformer

In high-voltage and large-capacity power distribution scenarios, the problem of insufficient equipment capacity and low grid conne…

View model
16000 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
16,000 kVA 110 kV

16000 kVA 110 kV Oil-Immersed power Transformer

In the ultra-high voltage and ultra-large capacity power transmission process, excessive system losses and insufficient equipment…

View model
20000 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
20,000 kVA 110 kV

20000 kVA 110 kV Oil-Immersed power Transformer

In the ultra-large capacity power distribution scenarios, the weak load-bearing capacity of equipment and the high grid connection…

View model
25000 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
25,000 kVA 110 kV

25000 kVA 110 kV Oil-Immersed power Transformer

Currently, the fields of high-voltage power transmission and large power station support are generally facing industry pain points…

View model
31500 kVA 110 kV Oil-Immersed power Transformer — Fengguang Transformer 110kV Power Transformer
31,500 kVA 110 kV

31500 kVA 110 kV Oil-Immersed power Transformer

In the ultra-large capacity power distribution scenarios, the insufficient shock resistance of equipment and the excessive power l…

View model
2500 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
2,500 kVA 220 kV

2500 kVA 220 kV Oil-Immersed power Transformer

In the 220KV high-voltage and small-capacity power distribution scenarios, the lack of equipment compatibility and high energy con…

View model
3150 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
3,150 kVA 220 kV

3150 kVA 220 kV Oil-Immersed power Transformer

In the 220KV high-voltage medium-low capacity power distribution scenarios, the high equipment energy consumption and insufficient…

View model
6300 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
6,300 kVA 220 kV

6300 kVA 220 kV Oil-Immersed power Transformer

Currently, in the field of high-voltage power distribution, there are industry pain points such as low Energy Efficiency of large-…

View model
12500 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
12,500 kVA 220 kV

12500 kVA 220 kV Oil-Immersed power Transformer

Currently, in the field of high-voltage power distribution, there are industry pain points such as low Energy Efficiency of large-…

View model
20000 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
20,000 kVA 220 kV

20000 kVA 220 kV Oil-Immersed power Transformer

In the 220KV high-voltage power distribution scenario, the insufficient insulation performance of equipment and the poor stability…

View model
63000 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
63,000 kVA 220 kV

63000 kVA 220 kV Oil-Immersed power Transformer

In the 220KV large-scale power distribution scenarios, the equipment's carrying capacity is insufficient and the coordination of t…

View model
75000 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
75,000 kVA 220 kV

75000 kVA 220 kV Oil-Immersed power Transformer

In the 220KV large-scale hub power distribution scenarios, the lack of equipment intelligence and the high transmission loss under…

View model
90000 kVA 220 kV Oil-Immersed power Transformer — Fengguang Transformer 220kV Power Transformer
90,000 kVA 220 kV

90000 kVA 220 kV Oil-Immersed power Transformer

In the 220KV large-scale hub power distribution scenarios, the lack of equipment load redundancy and weak customization adaptabili…

View model

Selection notes

How to read this family

Large power transformers sit between generation and the transmission grid, or between a high-voltage grid and a large industrial load. They are engineered around the system study, not selected from a catalogue.

Fengguang builds 110 kV and 220 kV oil-immersed power transformers from 6.3 to 120 MVA. Typical duties include generator step-up, substation step-down, grid interconnection and renewable-energy collection. The design covers the core, windings, tap changer, cooling, bushings, monitoring and test plan as one system.

Every project starts with the single-line diagram, fault level, load profile, grid code and site conditions. Impedance, cooling, tap range, insulation level and transport limits are agreed before design. Routine, type and special tests are documented to IEC 60076, and a witness test can be arranged.

Buyer questions

Questions to settle before the datasheet

What capacity range do you build?
The large power range covers 6.3 to 120 MVA at 110 kV and 220 kV. Higher ratings and other voltage classes can be reviewed as a project-specific design.
Can you supply generator step-up transformers?
Yes. Generator step-up units are designed around the generator rating, fault level, grid code and step-up ratio. The interface with the generator circuit breaker and the unit auxiliary transformer is part of the review.
What cooling types are available?
ONAN, ONAF and OFAF are available. The cooling choice depends on the ambient temperature, load profile, noise limit and the allowed footprint.
How are large transformers shipped?
Transport limits are agreed early. The tank, bushings and cooling equipment may be shipped separately, and the site assembly and oil-filling procedure is included in the documentation.