35kV On-Load Tap-Changing Transformer
Standards
GB / IEC 60076
Testing
Routine report
Origin
China
35kV On-Load Tap-Changing Transformers
1600 kVA 35 kV Oil-Immersed power Transformer
The industry's pain points mainly lie in the insufficient stability of high- Power Distribution Equipment , the difficulty in expansion, and the poor adaptability. Your problem is that it is difficult to find a power supply device that can adapt to high-load scenarios, balance cost performance and ease of operation. We have specially developed a 1600KVA/ 35kv Transformer , which can be flexibly combined with Dry Type Transformer or Oil Immersed Transformer , and is paired with High And Low Voltage Switchgear to achieve precise power distribution. In practical applications, it can stably carry a power load of around 1280kW, effectively solving the problem of unstable power supply in high-load scenarios, and reducing operation and maintenance costs. The core value of this product lies in achieving efficient conversion from 35KV high voltage to 0.4KV low voltage, adapting to heavy-load scenarios such as large-scale industries and new energy, and can operate in conjunction with Box Type Substation and Electric Power Converter , or connect to Combined Photovoltaic Substations for grid connection, ensuring efficient, safe and reliable power transmission.
- Product type
- 35kV On-Load Tap-Changing Transformer
- Rated capacity
- 1,600 kVA
- Voltage class
- 35 kV
- Cooling
- ONAN / ONAF
- Tap range
- Off-circuit or on-load, project-specific
- Winding
- Copper or aluminium (project-specific)
Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.
- Routine test report with the unit
- English GA drawing and O&M manual
- Copper or aluminium winding options
- 50 Hz / 60 Hz and harsh-site options
Product overview
The industry's pain points mainly lie in the insufficient stability of high- Power Distribution Equipment , the difficulty in expansion, and the poor adaptability. Your problem is that it is difficult to find a power supply device that can adapt to high-load scenarios, balance cost performance and ease of operation. We have specially developed a 1600KVA/ 35kv Transformer , which can be flexibly combined with Dry Type Transformer or Oil Immersed Transformer , and is paired with High And Low Voltage Switchgear to achieve precise power distribution. In practical applications, it can stably carry a power load of around 1280kW, effectively solving the problem of unstable power supply in high-load scenarios, and reducing operation and maintenance costs. The core value of this product lies in achieving efficient conversion from 35KV high voltage to 0.4KV low voltage, adapting to heavy-load scenarios such as large-scale industries and new energy, and can operate in conjunction with Box Type Substation and Electric Power Converter , or connect to Combined Photovoltaic Substations for grid connection, ensuring efficient, safe and reliable power transmission.
1.High load adaptability is outstanding: Specifically designed for high-load scenarios, it can stably handle the power consumption of large motors, production lines and other heavy-load equipment. It can seamlessly connect with Combined Photovoltaic Substations and Electric Power Converters, meeting the requirements for grid connection of new energy and industrial heavy-load power distribution. When paired with Box Type Substation, it can achieve integrated power distribution.
2. Safe and Easy Maintenance: The Oil Immersed Transformer adopts an anti-corrosion and sealed design, suitable for outdoor harsh environments with excellent heat dissipation performance; The Dry Type Transformer has outstanding fire resistance and is suitable for indoor enclosed scenarios. Both are equipped with simple maintenance designs. When combined with High And Low Voltage Switchgear, they can quickly identify faults and reduce maintenance complexity.
1.The selection should take into account the peak load. If it is used in a new energy project, it is recommended to combine with Combined Photovoltaic Substations and Electric Power Converter to ensure grid connection stability; for outdoor heavy-load scenarios, Oil Immersed Transformer should be preferred, and for indoor precision scenarios, Dry Type Transformer should be selected.
2. Daily operation and maintenance mainly focus on monitoring the temperature rise of equipment. For oil-immersed transformers, regular inspections of the oil condition are necessary. For dry-type transformers, ensure proper ventilation and dryness around the unit to prevent the accumulation of debris that could hinder heat dissipation.
Design features
What the design is built around
Low-loss magnetic core
Cold-rolled grain-oriented silicon steel and a stepped core reduce no-load loss and audible noise.
Sealed tank construction
Welded tank, quality-gasketed cover and pressure-tested seals reduce oil leakage risk in outdoor duty.
Thermal margin for hot climates
Cooling surfaces and oil volume are selected for high ambient temperature and cyclic loading.
System compatibility
MV terminals, cable boxes and LV bushings are matched to the switchgear and protection scheme.
Typical specification
Specifications to confirm on the datasheet
| Product type | 35kV On-Load Tap-Changing Transformer |
|---|---|
| Rated capacity | 1,600 kVA |
| Voltage class | 35 kV |
| Cooling | ONAN / ONAF |
| Tap range | Off-circuit or on-load, project-specific |
| Winding | Copper or aluminium (project-specific) |
| Standards | GB 1094.1, GB/T 6451, IEC 60076 |
| Testing | Routine tests plus type and special tests on request |
The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.
Typical applications
- 35 kV industrial main substations
- Utility distribution with voltage regulation
- Steel, cement and chemical plants
- Renewable-energy step-up
- Mining and oil-gas facilities
Confirm before ordering
- Rated capacity, voltage ratio and tap range
- Impedance, fault level and parallel operation
- Ambient temperature, altitude and enclosure
- Winding material, losses and efficiency class
- Terminations, protection and monitoring
- Tests, inspection, packing and shipping limits
Buyer questions
FAQ for 1600 kVA 35 kV Oil-Immersed power Transformer
What is 1600 kVA 35 kV Oil-Immersed power Transformer best used for?
What is the typical lead time for 1600 kVA 35 kV Oil-Immersed power Transformer?
Which standards and tests are supplied?
Can the transformer be customised for 60 Hz or a hot climate?
How do I choose between copper and aluminium windings?
Related models
Other configurations in this family
35kV On-Load Tap-Changing Transformer
1600 kVA 35 kV Oil-Immersed Transformer High Efficiency
High-Efficiency 1600KVA 35KV Oil-immersed Transformer Adapted to Multiple Power Transmission Scenarios
View model
35kV On-Load Tap-Changing Transformer
2000 kVA 35 kV Oil-Immersed power Transformer
The industry's pain points lie in the difficulties of integrating ultra-large-capacity Power Distribution Equipment at the grid le…
View model
35kV On-Load Tap-Changing Transformer
2000 kVA 35 kV Oil-Immersed Transformer Pure Copper
35KV 2000KVA All-Copper Oil-immersed Transformer : Stable Power Supply for Multiple Power Engineering Scenarios
View model
35kV On-Load Tap-Changing Transformer
1000 kVA 35 kV Oil-Immersed power Transformer
The core of the industry's pain points lies in the poor adaptability of medium and high voltage Power Distribution Equipment , the…
View model
35kV On-Load Tap-Changing Transformer
1000 kVA 35 kV Oil-Immersed Transformer Low Loss
Low-Loss 35KV 1000KVA Oil-immersed Transformer for Stable Power Supply in Industrial Power Distribution
View model
35kV On-Load Tap-Changing Transformer
3150 kVA 35 kV Oil-Immersed power Transformer
The industry's pain points lie in the insufficient stability of ultra-high- Power Distribution Equipment , the high difficulty of…
View modelProject inquiry
Tell us what the transformer has to do.