Fengguang Transformer
8000 kVA 35 kV Oil-Immersed Transformer Low Loss — Fengguang Transformer 35kV On-Load Tap-Changing Transformer

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

35kV On-Load Tap-Changing Transformers

8000 kVA 35 kV Oil-Immersed Transformer Low Loss

8,000 kVA 35 kV 35kV On-Load Tap-Changing Transformer

8000KVA 35KV Low Loss Oil Immersed Transformer - Industrial Power Voltage Stabilization and Transmission Equipment Currently, power transmission and distribution equipment commonly suffers from high no-load losses and high operating energy consumption. Many industrial and mining enterprises and substations often face the challenges of high equipment maintenance costs and excessive power consumption during long-term operation. To address these issues, this 8000KVA 35KV Low Loss Oil Immersed Transformer precisely solves the high energy consumption problem of power equipment by optimizing the core structure and winding process. It can effectively reduce equipment operating losses and improve power transmission stability, achieving the core effects of energy saving, consumption reduction, and stable power supply for large and medium-sized power engineering projects. This equipment is a core component of power transmission and distribution systems and is often used in conjunction with Dry Type Transformers, Box Type Substations, High And Low Voltage Switchgear , Electric Power Converters, and Combined Photovoltaic Substations . It is widely used in factory power distribution, photovoltaic power plants, municipal substations, and other scenarios, adapting to high-voltage power conversion and voltage stabilization transmission requirements. Core Product Features 1. Ultra-low Loss Energy-Saving Design: Utilizing a high-permeability silicon steel core and optimized lamination process, it significantly reduces no-load and load losses. Long-term operation can significantly reduce enterprise electricity consumption expenditures and is suitable for long-term continuous operation. Practical Maintenance Tips 1. During equipment operation, it is necessary to regularly check the insulating oil level and oil temperature, maintain smooth ventilation and heat dissipation, and avoid high-temperature overload operation. This can effectively extend the service life of the equipment and ensure power supply stability. Frequently Asked Questions (

Quick answer. 8000 kVA 35 kV Oil-Immersed Transformer Low Loss is a 35kV On-Load Tap-Changing Transformer rated 8,000 kVA at 35 kV. Typical applications include 35 kV industrial main substations, Utility distribution with voltage regulation, Steel, cement and chemical plants. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
35kV On-Load Tap-Changing Transformer
Rated capacity
8,000 kVA
Voltage class
35 kV
Cooling
ONAN / ONAF
Tap range
Off-circuit or on-load, project-specific
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

8000KVA 35KV Low Loss Oil Immersed Transformer - Industrial Power Voltage Stabilization and Transmission Equipment Currently, power transmission and distribution equipment commonly suffers from high no-load losses and high operating energy consumption. Many industrial and mining enterprises and substations often face the challenges of high equipment maintenance costs and excessive power consumption during long-term operation. To address these issues, this 8000KVA 35KV Low Loss Oil Immersed Transformer precisely solves the high energy consumption problem of power equipment by optimizing the core structure and winding process. It can effectively reduce equipment operating losses and improve power transmission stability, achieving the core effects of energy saving, consumption reduction, and stable power supply for large and medium-sized power engineering projects. This equipment is a core component of power transmission and distribution systems and is often used in conjunction with Dry Type Transformers, Box Type Substations, High And Low Voltage Switchgear , Electric Power Converters, and Combined Photovoltaic Substations . It is widely used in factory power distribution, photovoltaic power plants, municipal substations, and other scenarios, adapting to high-voltage power conversion and voltage stabilization transmission requirements. Core Product Features 1. Ultra-low Loss Energy-Saving Design: Utilizing a high-permeability silicon steel core and optimized lamination process, it significantly reduces no-load and load losses. Long-term operation can significantly reduce enterprise electricity consumption expenditures and is suitable for long-term continuous operation. Practical Maintenance Tips 1. During equipment operation, it is necessary to regularly check the insulating oil level and oil temperature, maintain smooth ventilation and heat dissipation, and avoid high-temperature overload operation. This can effectively extend the service life of the equipment and ensure power supply stability. Frequently Asked Questions (

Design features

What the design is built around

Low-loss magnetic core

Cold-rolled grain-oriented silicon steel and a stepped core reduce no-load loss and audible noise.

Sealed tank construction

Welded tank, quality-gasketed cover and pressure-tested seals reduce oil leakage risk in outdoor duty.

Thermal margin for hot climates

Cooling surfaces and oil volume are selected for high ambient temperature and cyclic loading.

System compatibility

MV terminals, cable boxes and LV bushings are matched to the switchgear and protection scheme.

Typical specification

Specifications to confirm on the datasheet

Product type 35kV On-Load Tap-Changing Transformer
Rated capacity 8,000 kVA
Voltage class 35 kV
Cooling ONAN / ONAF
Tap range Off-circuit or on-load, project-specific
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076
Testing Routine tests plus type and special tests on request

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • 35 kV industrial main substations
  • Utility distribution with voltage regulation
  • Steel, cement and chemical plants
  • Renewable-energy step-up
  • Mining and oil-gas facilities

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 8000 kVA 35 kV Oil-Immersed Transformer Low Loss

What is 8000 kVA 35 kV Oil-Immersed Transformer Low Loss best used for?
This model is specified at 8,000 kVA and 35 kV. It is used where the site load, fault level and environmental conditions match the approved datasheet. Share the load profile, ambient temperature, altitude and grid code and the design can be checked against the application.
What is the typical lead time for 8000 kVA 35 kV Oil-Immersed Transformer Low Loss?
Standard distribution units typically ship in 25-40 days after drawing approval. Large power transformers and integrated stations are scheduled by design review, core and winding production, tanking, testing and packing. The exact date is confirmed in the quotation.
Which standards and tests are supplied?
The transformer family is designed to GB 1094.1, GB/T 6451 and IEC 60076. Routine tests include winding resistance, ratio, impedance, no-load loss, load loss, insulation resistance and power-frequency withstand. Type and special tests are available on request.
Can the transformer be customised for 60 Hz or a hot climate?
Yes. Frequency, ambient temperature, altitude, enclosure, corrosion class and terminal arrangement are project inputs. The design is adjusted before production, and the approved datasheet becomes the inspection basis.
How do I choose between copper and aluminium windings?
Copper gives higher short-circuit strength and a more compact winding; aluminium can reduce first cost for lightly loaded units. The choice depends on fault level, load profile, loss evaluation and the buyer's specification. Both are available.

Related models

Other configurations in this family

All 35kV OLTC Transformer

Project inquiry

Tell us what the transformer has to do.

Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.

No phone, email or address is published on this site. Your details are used only to answer this inquiry.