Dry-Type Power Transformer Selection Guide

Quick answer. Fire-safe cast-resin transformers for buildings, data centres and industry. This guide covers the selection inputs, typical configuration and the questions t

Reviewed by the Fengguang engineering team · Last updated 10 Nov 2026

Dry-Type Power Transformer Selection Guide

Fire-safe cast-resin transformers for buildings, data centres and industry. This guide covers the selection inputs, typical configuration and the questions to settle before the datasheet is approved.

What this family covers

Fire-safe cast-resin transformers for buildings, data centres and industry.

Dry-type transformers replace insulating oil with cast epoxy resin or impregnated insulation. That removes the oil fire load and makes them a natural fit for indoor rooms, hospitals, data centres, metro stations and commercial buildings. Fengguang builds the SC(B)10, SC(B)13, SC(B)14 and SC(B)18 cast-resin families, plus the SC(B)H15 amorphous-alloy range. Capacities run from 30 to 2,500 kVA at 10 kV, 20 kV and 35

How to select

Start with the load in kVA, the voltage class, the fault level and the site conditions. Then choose the loss level, cooling, winding material, tap range and enclosure. Do not select from a catalogue without those inputs.

Typical configuration

Most projects start from a standard Dry-Type Power Transformer platform and adapt the cooling, terminals, protection and finish. The approved datasheet fixes the guaranteed values.

Questions to settle before the datasheet

Confirm the load profile, voltage ratio, tap range, impedance, fault level, cooling stage, ambient, altitude, enclosure, corrosion class, termination and test scope. These are the inputs that change the design.

Acceptance checks

Check the nameplate data, routine test report, dimensions, weight, painting, accessories and packing against the approved drawing. For critical projects, add a witnessed test and a document review.

InputWhat to confirm
CapacitykVA and load profile
VoltageClass, ratio and tap range
LossesNo-load and load loss
CoolingONAN/ONAF or AN/AF
EnvironmentAmbient, altitude, IP and corrosion

FAQ

How do I choose a Dry-Type Power Transformer?

Start from maximum demand, voltage class, fault level and site conditions. Then compare losses, cooling, dimensions and protection as a system.

Can the transformer be customised?

Yes. Winding material, losses, cooling, terminals, enclosure and finish are project options, confirmed on the approved datasheet.

What should be in the quotation?

Guaranteed losses, impedance, tap range, cooling stage, dimensions, weight, test scope, documents and delivery basis.

What is the most common selection error?

Sizing on connected load, ignoring ambient/altitude, or comparing models only on purchase price instead of total owning cost.