SC(B)H15 Amorphous Dry Transformer: Loss, Cooling and Protection

Quick answer. Amorphous-alloy cores cut no-load losses in low-load, long-running duty. This guide covers the selection inputs, typical configuration and the questions to s

Reviewed by the Fengguang engineering team · Last updated 10 Nov 2026

SC(B)H15 Amorphous Dry Transformer: Loss, Cooling and Protection

Amorphous-alloy cores cut no-load losses in low-load, long-running duty. This guide covers the selection inputs, typical configuration and the questions to settle before the datasheet is approved.

Losses

Compare guaranteed no-load and load loss at the reference temperature. The right loss level depends on the load profile, tariff and service life, not only the model name.

Cooling

Natural cooling is simpler; forced cooling adds capacity but also fans, auxiliary power and maintenance. State the ambient and altitude so the cooling stage is correct.

Protection

Confirm impedance, earthing, relay settings, cable entry and surge protection. The transformer must coordinate with the upstream and downstream protection.

Questions to settle before the datasheet

Confirm the load profile, voltage ratio, tap range, impedance, fault level, cooling stage, ambient, altitude, enclosure, corrosion class, termination and test scope. These are the inputs that change the design.

Acceptance checks

Check the nameplate data, routine test report, dimensions, weight, painting, accessories and packing against the approved drawing. For critical projects, add a witnessed test and a document review.

InputWhat to confirm
CapacitykVA and load profile
VoltageClass, ratio and tap range
LossesNo-load and load loss
CoolingONAN/ONAF or AN/AF
EnvironmentAmbient, altitude, IP and corrosion

FAQ

How do I choose a SC(B)H15 Amorphous Dry Transformer?

Start from maximum demand, voltage class, fault level and site conditions. Then compare losses, cooling, dimensions and protection as a system.

Can the transformer be customised?

Yes. Winding material, losses, cooling, terminals, enclosure and finish are project options, confirmed on the approved datasheet.

What should be in the quotation?

Guaranteed losses, impedance, tap range, cooling stage, dimensions, weight, test scope, documents and delivery basis.

What is the most common selection error?

Sizing on connected load, ignoring ambient/altitude, or comparing models only on purchase price instead of total owning cost.