Switch Cabinet Selection Guide

Quick answer. GGD, MNS, GCS and SF6 ring-main units for complete power distribution. This guide covers the selection inputs, typical configuration and the questions to set

Reviewed by the Fengguang engineering team · Last updated 10 Nov 2026

Switch Cabinet Selection Guide

GGD, MNS, GCS and SF6 ring-main units for complete power distribution. This guide covers the selection inputs, typical configuration and the questions to settle before the datasheet is approved.

What this family covers

GGD, MNS, GCS and SF6 ring-main units for complete power distribution.

Switch cabinets complete the distribution system. They provide incomers, busbars, feeders, protection, metering and isolation for the transformer and the loads downstream. Fengguang supplies GGD fixed-type low-voltage boards, MNS and GCS draw-out boards, and SF6 ring-main units for medium-voltage networks. The cabinets are matched to the transformer rating, fault level, outgoing circuits and protection scheme. T

How to select

Start with the load in kVA, the voltage class, the fault level and the site conditions. Then choose the loss level, cooling, winding material, tap range and enclosure. Do not select from a catalogue without those inputs.

Typical configuration

Most projects start from a standard Switch Cabinet platform and adapt the cooling, terminals, protection and finish. The approved datasheet fixes the guaranteed values.

Questions to settle before the datasheet

Confirm the load profile, voltage ratio, tap range, impedance, fault level, cooling stage, ambient, altitude, enclosure, corrosion class, termination and test scope. These are the inputs that change the design.

Acceptance checks

Check the nameplate data, routine test report, dimensions, weight, painting, accessories and packing against the approved drawing. For critical projects, add a witnessed test and a document review.

InputWhat to confirm
CapacitykVA and load profile
VoltageClass, ratio and tap range
LossesNo-load and load loss
CoolingONAN/ONAF or AN/AF
EnvironmentAmbient, altitude, IP and corrosion

FAQ

How do I choose a Switch Cabinet?

Start from maximum demand, voltage class, fault level and site conditions. Then compare losses, cooling, dimensions and protection as a system.

Can the transformer be customised?

Yes. Winding material, losses, cooling, terminals, enclosure and finish are project options, confirmed on the approved datasheet.

What should be in the quotation?

Guaranteed losses, impedance, tap range, cooling stage, dimensions, weight, test scope, documents and delivery basis.

What is the most common selection error?

Sizing on connected load, ignoring ambient/altitude, or comparing models only on purchase price instead of total owning cost.