SC(B)10 Type Dry-Type Transformers

30 kVA 20 kV Dry-Type Transformer Pure Copper

30 kVA 20 kV SC(B)10 Cast-Resin Dry-Type Transformer

1000KVA 10KV Dry Type Transformer for Stable Power Supply in New Energy Projects

Quick answer. 30 kVA 20 kV Dry-Type Transformer Pure Copper is a SC(B)10 Cast-Resin Dry-Type Transformer rated 30 kVA at 20 kV. Typical applications include Commercial buildings, Light industry, Public infrastructure. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
SC(B)10 Cast-Resin Dry-Type Transformer
Rated capacity
30 kVA
Voltage class
20 kV
Insulation
Cast epoxy resin, Class F/H
Cooling
AN / AF
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

1000KVA 10KV Dry Type Transformer for Stable Power Supply in New Energy Projects

During the construction of new energy power plants, traditional power supply equipment is susceptible to interference from environmental humidity and dust. Oil-immersed transformers pose a risk of leakage and fire, making it difficult to meet the stringent standards of outdoor clean energy projects. Many investors struggle to balance equipment safety levels and site layout when building power generation systems, finding it difficult to simultaneously ensure operational stability and maintenance costs. We offer a 1000KVA 10KV Dry Type Transformer, suitable for various new energy power generation scenarios, and can be networked with Box Type Substations and High And Low Voltage Switchgear . Once deployed, it can continuously and stably undertake power conversion tasks, working with Electric Power Converters to regulate power quality. It is widely used in Combined Photovoltaic Substations to ensure the continuous transmission of clean energy.

This dry-type transformer, relying on mature insulation technology, is suitable for renewable energy scenarios such as photovoltaics and wind power, undertaking the core function of voltage step-up and step-down. Compared to oil-immersed equipment, it requires no oil storage space, boasts superior fire and moisture resistance, and can be directly installed in indoor power distribution rooms or inside outdoor enclosures in renewable energy sites. The equipment operates stably, handling voltage fluctuations caused by the intermittent nature of renewable energy generation. It can be combined with high and low voltage switchgear and prefabricated photovoltaic substations to build a complete power supply and distribution chain, significantly simplifying the overall power distribution layout of renewable energy projects and shortening the project construction cycle.

Design features

What the design is built around

Flame-retardant insulation structure, suitable for complex operating conditions in renewable energy projects; enhanced safety when used with Combined Photovoltaic Substations.

Excellent no-load loss control, reducing power loss in renewable energy power plants during long-term continuous operation.

Tips

Before installation, confirm site ventilation conditions to avoid densely stacking multiple electrical devices, which can cause heat accumulation and ensure the heat dissipation efficiency of the Dry Type Transformer.

Typical specification

Specifications to confirm on the datasheet

Product type SC(B)10 Cast-Resin Dry-Type Transformer
Rated capacity 30 kVA
Voltage class 20 kV
Insulation Cast epoxy resin, Class F/H
Cooling AN / AF
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076-11
Testing Routine tests, partial discharge and temperature-rise type tests

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • Commercial buildings
  • Light industry
  • Public infrastructure
  • District heating and cooling
  • Indoor distribution rooms

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 30 kVA 20 kV Dry-Type Transformer Pure Copper

Can this 1000KVA 10KV Dry Type Transformer be directly used with a Box Type Substation ?
Yes, the equipment size is compatible with the internal installation space of conventional prefabricated substations, and it uses a universal interface standard for High and Low Voltage Switchgear lines. It can be put into operation in new energy projects immediately after wiring and commissioning upon arrival.
Compared to an Oil Immersed Transformer , what are the differences in daily maintenance?
No need for regular oil level or oil quality checks; the focus is on monitoring winding temperature and surface dust accumulation. The maintenance process is simpler, and there is no risk of oil leakage or contamination.
Can on-site commissioning support be provided after delivery?
Technical personnel can be arranged to guide the connection with supporting equipment such as Electric Power Converters and photovoltaic prefabricated substations, and basic operation and maintenance training will be provided simultaneously.

Project inquiry

Tell us what the transformer has to do.

Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.

No phone, email or address is published on this site. Your details are used only to answer this inquiry.