Skip to content
Fengguang Transformer
2500 kVA 10 kV Dry-Type Transformer Low Loss — Fengguang Transformer SC(B)13 Low-Loss Dry-Type Transformer

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

SC(B)13 Type Dry-Type Transformers

2500 kVA 10 kV Dry-Type Transformer Low Loss

2,500 kVA 10 kV SC(B)13 Low-Loss Dry-Type Transformer

2500KVA 10KV Low Loss Dry Type Transformer : High-Efficiency Power Distribution Core Equipment

Quick answer. 2500 kVA 10 kV Dry-Type Transformer Low Loss is a SC(B)13 Low-Loss Dry-Type Transformer rated 2,500 kVA at 10 kV. Typical applications include Green buildings, Data centres, Industrial plants. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
SC(B)13 Low-Loss Dry-Type Transformer
Rated capacity
2,500 kVA
Voltage class
10 kV
Insulation
Cast epoxy resin, Class F/H
Cooling
AN / AF
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

2500KVA 10KV Low Loss Dry Type Transformer : High-Efficiency Power Distribution Core Equipment

Traditional oil-immersed transformers used in power distribution projects often face challenges such as high losses and stringent fire safety requirements. Many project owners deploy Power Distribution Equipment in data centers, raising concerns about persistently high energy consumption and unmanageable maintenance risks. We offer the 2500KVA 10KV Low Loss Dry Type Transformer, which leverages an optimized core winding structure to reduce no-load and load losses. Once operational, this equipment continuously reduces long-term electricity costs and is suitable for various enclosed indoor power distribution scenarios. This dry type transformer is widely used in commercial complexes, industrial plants, and photovoltaic (PV) sites. It is often used in conjunction with high-and-low voltage switchgear to build power distribution systems and can also be integrated into box-type substations. In the power conversion stage of Combined Photovoltaic Substations , it works in conjunction with an Electric Power Converter to stably complete voltage transformation, ensuring stable and reliable power transmission. The equipment does not use insulating oil, eliminating the risk of oil leakage and fire. It boasts strong operational stability and meets the stringent standards of modern infrastructure for safe and energy-efficient power distribution equipment.

Design features

What the design is built around

Low Loss Design

As a low-loss dry-type transformer, the core and windings undergo refined process adjustments, resulting in lower long-term energy consumption and significantly reducing project-wide operating costs.

Reliable Safety and Protection

With no liquid insulating medium, it offers excellent fire resistance and eliminates the need for additional oil storage facilities, making it suitable for compact indoor power distribution layouts.

Tips

Ensure sufficient ventilation space during installation to promptly dissipate heat generated during operation and ensure stable output under rated conditions.

Typical specification

Specifications to confirm on the datasheet

Product type SC(B)13 Low-Loss Dry-Type Transformer
Rated capacity 2,500 kVA
Voltage class 10 kV
Insulation Cast epoxy resin, Class F/H
Cooling AN / AF
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076-11
Testing Routine tests, partial discharge and temperature-rise type tests

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • Green buildings
  • Data centres
  • Industrial plants
  • Hospitals
  • Commercial complexes

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 2500 kVA 10 kV Dry-Type Transformer Low Loss

Is this 2500KVA 10KV Dry Type Transformer suitable for direct outdoor placement?
The standard model is recommended for indoor installation. For outdoor use, a dedicated protective casing is required to prevent continuous corrosion from rain and dust.
Is there a significant difference in daily maintenance workload compared to an Oil Immersed Transformer ?
No oil testing or insulation oil replacement is required. Regular surface cleaning is sufficient, simplifying the maintenance process.
What is the after-sales response timeline for equipment malfunctions?
Upon receiving feedback, technicians will conduct remote troubleshooting immediately. For major malfunctions, on-site technical support can be coordinated, and original factory spare parts will be provided.
Can it be directly installed into a Box Type Substation for use?
The dimensions meet the standards for built-in substations and can be integrated with High and Low Voltage Switchgears, allowing for complete integration as needed.

Related models

Other configurations in this family

All SC(B)13 Dry-Type Transformer

Project inquiry

Tell us what the transformer has to do.

Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.

No phone, email or address is published on this site. Your details are used only to answer this inquiry.