Skip to content
Fengguang Transformer
500 kVA 10 kV Dry-Type Transformer Pure Copper — Fengguang Transformer SC(B)13 Low-Loss Dry-Type Transformer

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

SC(B)13 Type Dry-Type Transformers

500 kVA 10 kV Dry-Type Transformer Pure Copper

500 kVA 10 kV SC(B)13 Low-Loss Dry-Type Transformer

500KVA 10KV Pure Copper Dry-Type Transformer: Dedicated Stabilizing Equipment for Industrial Power Distribution

Quick answer. 500 kVA 10 kV Dry-Type Transformer Pure Copper is a SC(B)13 Low-Loss Dry-Type Transformer rated 500 kVA at 10 kV. Typical applications include Green buildings, Data centres, Industrial plants. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
SC(B)13 Low-Loss Dry-Type Transformer
Rated capacity
500 kVA
Voltage class
10 kV
Insulation
Cast epoxy resin, Class F/H
Cooling
AN / AF
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

500KVA 10KV Pure Copper Dry-Type Transformer: Dedicated Stabilizing Equipment for Industrial Power Distribution

In the current power distribution industry, traditional transformer equipment generally suffers from pain points such as poor heat dissipation, flammability hazards, high losses, and cumbersome operation and maintenance. Many enterprises in factory power distribution, photovoltaic systems, and high-to-low voltage power conversion scenarios often face challenges related to insufficient equipment safety, short service life, and poor adaptability. To address these industry problems and user pain points, we are launching a 500KVA 10KV Pure copper Dry-Type Transformer. It utilizes pure copper winding technology combined with a dry-cast structure, replacing the drawbacks of the traditional Oil-immersed Transformer design. This equipment is perfectly compatible with Box Type Substations and Combined Photovoltaic Substations for various power distribution scenarios. It works in conjunction with High And Low Voltage Switchgear and Electric Power Converters, and is widely used in core scenarios such as factories, commercial buildings, photovoltaic power stations, and municipal power distribution. It effectively reduces power transmission losses, eliminates the risk of oil leaks and fires, requires no complex maintenance, and boasts strong long-term operational stability, significantly reducing the cost of equipment replacement and maintenance for enterprises.

This 500KVA 10KV pure copper dry-type transformer is a core foundational piece of equipment in medium and high voltage power distribution systems. Its core uses all-pure copper coils, which offer superior conductivity, lower heat generation, and stronger overload resistance compared to aluminum coil equipment. The dry-type, oil-free design completely avoids the safety hazards of oil-immersed equipment, providing advantages such as fire resistance, explosion protection, moisture resistance, and dust resistance. It can be directly installed and used indoors, suitable for various enclosed power distribution spaces. The equipment's rated capacity and voltage parameters are compatible with mainstream domestic industrial power distribution standards, allowing for flexible integration with various high and low voltage power distribution systems. Whether for conventional industrial power distribution upgrades or the construction of photovoltaic integrated substations, it enables stable and efficient power conversion and voltage regulation, making it the preferred equipment for upgrading industrial power systems.

Core Product Features

1. Low Energy Consumption with Pure Copper Winding: Utilizing high-purity copper coils, it boasts high conductivity and low resistance loss. Compared to conventional dry-type transformers, it consumes less energy during long-term operation, effectively improving power transmission efficiency and adapting to long-term uninterrupted operation scenarios.

2. Safe and Durable Dry-Type Structure: The oil-free dry-type design eliminates the oil leakage and explosion hazards of oil-immersed transformers. It offers excellent fire and moisture resistance, strong environmental adaptability, and a service life far exceeding that of ordinary Power Distribution Equipment .

Installation & maintenance notes

  • Sufficient ventilation and heat dissipation space should be reserved during equipment installation. Avoid enclosed accumulation of debris to significantly reduce operating temperature rise and extend equipment lifespan.
  • Minimal routine maintenance is required. Only quarterly cleaning of surface dust and checking of wiring tightness are needed to ensure stable operation and significantly reduce maintenance labor costs.
  • Frequently Asked Questions (FAQ)
  • Q1: Can this dry-type transformer be used in photovoltaic substations?
  • A1: Yes. The equipment is perfectly compatible with Combined Photovoltaic Substations and can be used with Electric Power Converters and High and Low Voltage Switchgear to meet the voltage regulation, stabilization, and distribution needs of photovoltaic power, demonstrating strong adaptability.
  • Q2: What are the advantages of this product compared to an Oil-Immersed Transformer?

Design features

What the design is built around

Cast-resin insulation

Epoxy resin encapsulation protects windings from dust, humidity and accidental contact.

Fire-safe design

No insulating oil is used, making the unit suitable for indoor and fire-sensitive buildings.

Low partial discharge

Vacuum casting and controlled curing keep partial discharge low over the service life.

Low noise

Core and clamping design reduce structure-borne noise for hospitals, offices and data centres.

Typical specification

Specifications to confirm on the datasheet

Product type SC(B)13 Low-Loss Dry-Type Transformer
Rated capacity 500 kVA
Voltage class 10 kV
Insulation Cast epoxy resin, Class F/H
Cooling AN / AF
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076-11
Testing Routine tests, partial discharge and temperature-rise type tests

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • Green buildings
  • Data centres
  • Industrial plants
  • Hospitals
  • Commercial complexes

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 500 kVA 10 kV Dry-Type Transformer Pure Copper

What is 500 kVA 10 kV Dry-Type Transformer Pure Copper best used for?
This model is specified at 500 kVA and 10 kV. It is used where the site load, fault level and environmental conditions match the approved datasheet. Share the load profile, ambient temperature, altitude and grid code and the design can be checked against the application.
What is the typical lead time for 500 kVA 10 kV Dry-Type Transformer Pure Copper?
Standard distribution units typically ship in 25-40 days after drawing approval. Large power transformers and integrated stations are scheduled by design review, core and winding production, tanking, testing and packing. The exact date is confirmed in the quotation.
Which standards and tests apply to dry-type transformers?
Dry-type units follow GB 1094.1, GB/T 6451 and IEC 60076-11. Routine tests cover winding resistance, ratio, impedance, no-load and load loss, insulation resistance and power-frequency withstand. Partial-discharge and temperature-rise type tests are available.
Can a dry-type transformer be installed outdoors?
A standard cast-resin unit is intended for indoor, well-ventilated rooms. For outdoor use an IP enclosure, anti-condensation heaters and a corrosion class must be specified. In many coastal or dusty sites an oil-immersed or prefabricated station is a better fit.
How do I choose between copper and aluminium windings?
Copper gives higher short-circuit strength and a more compact winding; aluminium can reduce first cost for lightly loaded units. The choice depends on fault level, load profile, loss evaluation and the buyer's specification. Both are available.

Project inquiry

Tell us what the transformer has to do.

Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.

No phone, email or address is published on this site. Your details are used only to answer this inquiry.