315 kVA amorphous alloy type Dry-Type Transformer — Fengguang Transformer SC(B)H15 Amorphous Alloy Dry-Type Transformer

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

SC(B)H15 Amorphous Alloy Dry Transformers

315 kVA amorphous alloy type Dry-Type Transformer

315 kVA SC(B)H15 Amorphous Alloy Dry-Type Transformer

The current distribution field is generally facing industry pain points such as high energy consumption and high operation and maintenance costs. Traditional Oil Immersed Transformers are prone to safety hazards and have caused long-term troubles for enterprises. We have launched the 315KVA amorphous alloy type dry-type transformer, which is based on the non-ferrous alloy core technology. It provides users with efficient and reliable distribution solutions and has achieved significant energy consumption reduction and safety improvement in practical applications. This product belongs to the upgraded category of Dry Type Transformers and is widely applicable to scenarios such as Combined Photovoltaic Substations and Box Type Substations. It can also work in coordination with High And Low Voltage Switchgear , Electric Power Converter , etc., and is suitable for various scenarios such as industrial and commercial distribution, photovoltaic grid connection, and mine power supply, bringing stable and efficient power guarantees to users.

Quick answer. 315 kVA amorphous alloy type Dry-Type Transformer is a SC(B)H15 Amorphous Alloy Dry-Type Transformer rated 315 kVA. Typical applications include Data centres with long low-load hours, Commercial buildings, Street lighting and utilities. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
SC(B)H15 Amorphous Alloy Dry-Type Transformer
Rated capacity
315 kVA
Voltage class
10 kV / 20 kV / 35 kV
Insulation
Cast epoxy resin, Class F/H
Cooling
AN / AF
Winding
Copper or aluminium (project-specific)

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

The current distribution field is generally facing industry pain points such as high energy consumption and high operation and maintenance costs. Traditional Oil Immersed Transformers are prone to safety hazards and have caused long-term troubles for enterprises. We have launched the 315KVA amorphous alloy type dry-type transformer, which is based on the non-ferrous alloy core technology. It provides users with efficient and reliable distribution solutions and has achieved significant energy consumption reduction and safety improvement in practical applications. This product belongs to the upgraded category of Dry Type Transformers and is widely applicable to scenarios such as Combined Photovoltaic Substations and Box Type Substations. It can also work in coordination with High And Low Voltage Switchgear , Electric Power Converter , etc., and is suitable for various scenarios such as industrial and commercial distribution, photovoltaic grid connection, and mine power supply, bringing stable and efficient power guarantees to users.

Design features

What the design is built around

Ultra-low no-load loss

Utilizing amorphous alloy core material, compared to traditional silicon steel sheet transformers, the no-load loss is reduced by approximately 70%. This results in significant electricity cost savings over the long term, especially suitable for industrial and photovoltaic scenarios with fluctuating load rates.

High safety and stability

Oil-free design eliminates the risks of fire and explosion, making it suitable for indoor and densely populated areas with high safety requirements. It also has moisture-proof and dust-proof features, and can adapt to complex working conditions.

Purchase and Usage Tips

When installing, ensure there is sufficient space for heat dissipation. Avoid stacking the device too closely with other devices to allow for proper ventilation and heat dissipation, thereby extending the service life of the equipment.

During daily maintenance, there is no need to replace the insulating oil. Just clean the surface dust regularly and check the tightness of the connection terminals. This approach results in low operating costs.

Typical specification

Specifications to confirm on the datasheet

Product type SC(B)H15 Amorphous Alloy Dry-Type Transformer
Rated capacity 315 kVA
Voltage class 10 kV / 20 kV / 35 kV
Insulation Cast epoxy resin, Class F/H
Cooling AN / AF
Winding Copper or aluminium (project-specific)
Standards GB 1094.1, GB/T 6451, IEC 60076-11
Testing Routine tests, partial discharge and temperature-rise type tests

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • Data centres with long low-load hours
  • Commercial buildings
  • Street lighting and utilities
  • Renewable-energy auxiliary systems
  • Low-load industrial duty

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for 315 kVA amorphous alloy type Dry-Type Transformer

What is 315 kVA amorphous alloy type Dry-Type Transformer best used for?
This model is specified at 315 kVA and 10 kV / 20 kV / 35 kV. It is used where the site load, fault level and environmental conditions match the approved datasheet. Share the load profile, ambient temperature, altitude and grid code and the design can be checked against the application.
What is the typical lead time for 315 kVA amorphous alloy type Dry-Type Transformer?
Standard distribution units typically ship in 25-40 days after drawing approval. Large power transformers and integrated stations are scheduled by design review, core and winding production, tanking, testing and packing. The exact date is confirmed in the quotation.
Which standards and tests apply to dry-type transformers?
Dry-type units follow GB 1094.1, GB/T 6451 and IEC 60076-11. Routine tests cover winding resistance, ratio, impedance, no-load and load loss, insulation resistance and power-frequency withstand. Partial-discharge and temperature-rise type tests are available.
Can a dry-type transformer be installed outdoors?
A standard cast-resin unit is intended for indoor, well-ventilated rooms. For outdoor use an IP enclosure, anti-condensation heaters and a corrosion class must be specified. In many coastal or dusty sites an oil-immersed or prefabricated station is a better fit.
How do I choose between copper and aluminium windings?
Copper gives higher short-circuit strength and a more compact winding; aluminium can reduce first cost for lightly loaded units. The choice depends on fault level, load profile, loss evaluation and the buyer's specification. Both are available.

Project inquiry