Skip to content
Fengguang Transformer
Type MNS Drawout Distribution Switchgear — Fengguang Transformer Switchgear / Switch Cabinet

Standards

GB / IEC 60076

Testing

Routine report

Origin

China

Switchgear & Switch Cabinets

Type MNS Drawout Distribution Switchgear

Switchgear / Switch Cabinet

Type KYIN28A-12 Indoor AC High-Voltage Metal-Clad Drawout Switchgear is suitable for indoor assembled power distribution scenarios with three-phase AC 50Hz, rated voltage of 12KV, and operating current up to 4000A. It can receive and distribute electrical energy in places such as power plants, substations, industrial and mining enterprises, implement control, protection and monitoring of circuits, and also meet the needs of frequent operations.

Quick answer. Type MNS Drawout Distribution Switchgear is a Switchgear / Switch Cabinet. Typical applications include Low-voltage distribution, MV ring-main networks, Industrial control rooms. It is designed to GB 1094.1 and IEC 60076, with routine tests recorded against the approved datasheet.
Product type
Switchgear / Switch Cabinet
Rated voltage
0.4 kV / 12 kV / 40.5 kV (model dependent)
Busbar
Copper or aluminium, project-specific current rating
Protection
IP30-IP54, form 3b/4a options
Standards
IEC 61439 / GB 7251 series
Configuration
Fixed, draw-out or ring-main unit

Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.

  • Routine test report with the unit
  • English GA drawing and O&M manual
  • Copper or aluminium winding options
  • 50 Hz / 60 Hz and harsh-site options
GB 1094.1· GB/T 6451· IEC 60076· ISO 9001 / 14001 / 45001· CE where applicable

Product overview

Type KYIN28A-12 Indoor AC High-Voltage Metal-Clad Drawout Switchgear is suitable for indoor assembled power distribution scenarios with three-phase AC 50Hz, rated voltage of 12KV, and operating current up to 4000A. It can receive and distribute electrical energy in places such as power plants, substations, industrial and mining enterprises, implement control, protection and monitoring of circuits, and also meet the needs of frequent operations.

Design features

What the design is built around

This equipment has multiple advantages

it is equipped with a safe and reliable "five-prevention" interlocking device, which can prevent five types of electrical misoperations; it can flexibly select and configure various vacuum circuit breakers such as ZN63A (VS1) and VD4, as well as V07 vacuum contactor load switches, disconnectors, etc.; the handcart is divided into circuit breaker handcart, voltage transformer handcart, etc. according to purposes, and the handcarts for the same purpose have good interchangeability; heaters can be added to the circuit breaker compartment and cable compartment to avoid condensation and corrosion; the enclosure protection level reaches IP4X, and the protection level is IP2X when the compartment or circuit breaker compartment door is open.

Product Structure

The equipment consists of two parts

the cabinet body and the withdrawable handcart. The cabinet body is made of aluminum-zinc coated steel plate, and is divided into a circuit breaker compartment (handcart compartment), a main busbar compartment, a cable compartment and a relay instrument compartment by metal partitions; all metal structures are reliably grounded, and the main busbar compartment and the circuit breaker compartment are equipped with independent pressure release channels.

We independently design and manufacture the following four major product categories

Oil Immersed Transformer , Dry Type Transformer , Box Type Substation , High And Low Voltage Switchgear , please feel free to contact us.

Typical specification

Specifications to confirm on the datasheet

Product type Switchgear / Switch Cabinet
Rated voltage 0.4 kV / 12 kV / 40.5 kV (model dependent)
Busbar Copper or aluminium, project-specific current rating
Protection IP30-IP54, form 3b/4a options
Standards IEC 61439 / GB 7251 series
Configuration Fixed, draw-out or ring-main unit
Finish Powder-coated steel, project colour
Documentation Type test reports, routine test certificate, GA drawings

The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.

Typical applications

  • Low-voltage distribution
  • MV ring-main networks
  • Industrial control rooms
  • Commercial buildings
  • Renewable-energy auxiliary systems

Confirm before ordering

  • Rated capacity, voltage ratio and tap range
  • Impedance, fault level and parallel operation
  • Ambient temperature, altitude and enclosure
  • Winding material, losses and efficiency class
  • Terminations, protection and monitoring
  • Tests, inspection, packing and shipping limits

Buyer questions

FAQ for Type MNS Drawout Distribution Switchgear

What is Type MNS Drawout Distribution Switchgear best used for?
This model is specified at the required capacity and 10 kV / 20 kV / 35 kV. It is used where the site load, fault level and environmental conditions match the approved datasheet. Share the load profile, ambient temperature, altitude and grid code and the design can be checked against the application.
How is a switch cabinet matched to a transformer?
The cabinet is selected from the transformer rating, fault level, outgoing circuits and protection scheme. Busbar current, short-circuit withstand, IP rating and cable entry are confirmed on the single-line diagram before production.
Which standards and tests are supplied?
The transformer family is designed to GB 1094.1, GB/T 6451 and IEC 60076. Routine tests include winding resistance, ratio, impedance, no-load loss, load loss, insulation resistance and power-frequency withstand. Type and special tests are available on request.
Can the transformer be customised for 60 Hz or a hot climate?
Yes. Frequency, ambient temperature, altitude, enclosure, corrosion class and terminal arrangement are project inputs. The design is adjusted before production, and the approved datasheet becomes the inspection basis.
How do I choose between copper and aluminium windings?
Copper gives higher short-circuit strength and a more compact winding; aluminium can reduce first cost for lightly loaded units. The choice depends on fault level, load profile, loss evaluation and the buyer's specification. Both are available.

Project inquiry

Tell us what the transformer has to do.

Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.

No phone, email or address is published on this site. Your details are used only to answer this inquiry.