SC(B)18 Ultra-Low-Loss Dry-Type Transformer
Standards
GB / IEC 60076
Testing
Routine report
Origin
China
SC(B)18 Type Dry-Type Transformers
SC(B)18 Three-Phase Dry-Type Power Transformer
Currently, there are industry pain points in the medium-voltage power distribution field, such as weak anti-interference ability of equipment and limited applicable scenarios. Purchasers face difficulties in selecting and adapting, as well as high costs for later operation and maintenance. We have launched the SC(B)18 Three-Phase Dry Type Power Transformer (SC(B)18 type three-phase Dry-Type Power Transformer ), as an upgraded version of Dry Type Transformer , precisely addressing these industry pain points. The core value lies in balancing anti-interference ability and adaptability flexibility. It can form a complementary layout with Oil Immersed Transformer , meet the photovoltaic matching requirements of Combined Photovoltaic Substations , be used in combination with High And Low Voltage Switchgear and Electric Power Converter , seamlessly connect with Box Type Substation , and be widely applied in scenarios with high requirements for power supply quality such as precision manufacturing, photovoltaic power stations, and high-end parks, achieving the practical effect of stable power supply and convenient operation and maintenance, and filling the market adaptation gap of high-end three-phase dry-type transformers.
- Product type
- SC(B)18 Ultra-Low-Loss Dry-Type Transformer
- Rated capacity
- 30-2,500 kVA
- Voltage class
- 10 kV / 20 kV / 35 kV
- Insulation
- Cast epoxy resin, Class F/H
- Cooling
- AN / AF
- Winding
- Copper or aluminium (project-specific)
Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.
- Routine test report with the unit
- English GA drawing and O&M manual
- Copper or aluminium winding options
- 50 Hz / 60 Hz and harsh-site options
Product overview
Currently, there are industry pain points in the medium-voltage power distribution field, such as weak anti-interference ability of equipment and limited applicable scenarios. Purchasers face difficulties in selecting and adapting, as well as high costs for later operation and maintenance. We have launched the SC(B)18 Three-Phase Dry Type Power Transformer (SC(B)18 type three-phase Dry-Type Power Transformer ), as an upgraded version of Dry Type Transformer , precisely addressing these industry pain points. The core value lies in balancing anti-interference ability and adaptability flexibility. It can form a complementary layout with Oil Immersed Transformer , meet the photovoltaic matching requirements of Combined Photovoltaic Substations , be used in combination with High And Low Voltage Switchgear and Electric Power Converter , seamlessly connect with Box Type Substation , and be widely applied in scenarios with high requirements for power supply quality such as precision manufacturing, photovoltaic power stations, and high-end parks, achieving the practical effect of stable power supply and convenient operation and maintenance, and filling the market adaptation gap of high-end three-phase dry-type transformers.
Design features
What the design is built around
Outstanding Anti-Interference Capability
Utilizing an upgraded insulation structure, this product has a significantly enhanced anti-electromagnetic interference ability compared to ordinary Dry Type Transformers. When used in conjunction with High And Low Voltage Switchgear, it can prevent voltage fluctuations and ensure stable power supply for precision equipment, making it suitable for high-end industrial environments.
Flexible Adaptability
According to different power distribution requirements, it can seamlessly connect with Box Type Substation and Electric Power Converter without the need for complex renovations. At the same time, it is compatible with the photovoltaic power transmission requirements of Combined Photovoltaic Substations, making it suitable for various types of medium-voltage power distribution scenarios.
Tips
This product has a three-phase structure. Before purchasing, it is necessary to confirm the three-phase power supply requirements of the project to avoid mismatch in single-phase scenarios. In daily use, avoid exposing the equipment to damp environments to extend its service life.
Typical specification
Specifications to confirm on the datasheet
| Product type | SC(B)18 Ultra-Low-Loss Dry-Type Transformer |
|---|---|
| Rated capacity | 30-2,500 kVA |
| Voltage class | 10 kV / 20 kV / 35 kV |
| Insulation | Cast epoxy resin, Class F/H |
| Cooling | AN / AF |
| Winding | Copper or aluminium (project-specific) |
| Standards | GB 1094.1, GB/T 6451, IEC 60076-11 |
| Testing | Routine tests, partial discharge and temperature-rise type tests |
The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.
Typical applications
- Net-zero buildings
- Hyperscale and edge data centres
- Hospitals and laboratories
- Premium commercial projects
- Industrial energy upgrades
Confirm before ordering
- Rated capacity, voltage ratio and tap range
- Impedance, fault level and parallel operation
- Ambient temperature, altitude and enclosure
- Winding material, losses and efficiency class
- Terminations, protection and monitoring
- Tests, inspection, packing and shipping limits
Buyer questions
FAQ for SC(B)18 Three-Phase Dry-Type Power Transformer
What is SC(B)18 Three-Phase Dry-Type Power Transformer best used for?
What is the typical lead time for SC(B)18 Three-Phase Dry-Type Power Transformer?
Which standards and tests apply to dry-type transformers?
Can a dry-type transformer be installed outdoors?
How do I choose between copper and aluminium windings?
Related models
Other configurations in this family
SC(B)18 Ultra-Low-Loss Dry-Type Transformer
SCB18 Resin Cast Dry-Type Transformer
Currently, in the medium-voltage power distribution field, there are industry pain points such as poor equipment temperature resis…
View model
SC(B)18 Ultra-Low-Loss Dry-Type Transformer
SCB18 Resin-Insulated Dry-Type Power Transformer
In the current medium-voltage power distribution field, traditional Dry Type Transformers often encounter industry challenges such…
View modelProject inquiry
Tell us what the transformer has to do.
Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.