SC(B)18 Type Dry-Type Transformers
SCB18 Resin Cast Dry-Type Transformer
Currently, in the medium-voltage power distribution field, there are industry pain points such as poor equipment temperature resistance and easy aging of insulation. Purchasers face difficulties in selecting models, short equipment lifespan, and high operation and maintenance costs. We have launched the SCB18 Resin Cast Dry Type Transformer , as the high-end model of Dry Type Transformer, with the core technology of resin casting process, precisely solving the industry pain points. Its core value lies in high temperature resistance and strong insulation, and it can complement Oil Immersed Transformer , meeting the photovoltaic matching requirements of Combined Photovoltaic Substations . It can be used in combination with High And Low Voltage Switchgear and Electric Power Converter , seamlessly connecting Box Type Substation . It is widely applied in industrial power distribution, high-end parks, photovoltaic power stations, etc., achieving long-term stable power supply and reducing operation and maintenance costs, filling the high-end market gap of resin cast dry-type transformers.
- Product type
- SC(B)18 Ultra-Low-Loss Dry-Type Transformer
- Rated capacity
- 30-2,500 kVA
- Voltage class
- 10 kV / 20 kV / 35 kV
- Insulation
- Cast epoxy resin, Class F/H
- Cooling
- AN / AF
- Winding
- Copper or aluminium (project-specific)
Final ratings, losses, impedance and dimensions are confirmed on the approved datasheet. Website values are for family selection.
- Routine test report with the unit
- English GA drawing and O&M manual
- Copper or aluminium winding options
- 50 Hz / 60 Hz and harsh-site options
Product overview
Currently, in the medium-voltage power distribution field, there are industry pain points such as poor equipment temperature resistance and easy aging of insulation. Purchasers face difficulties in selecting models, short equipment lifespan, and high operation and maintenance costs. We have launched the SCB18 Resin Cast Dry Type Transformer , as the high-end model of Dry Type Transformer, with the core technology of resin casting process, precisely solving the industry pain points. Its core value lies in high temperature resistance and strong insulation, and it can complement Oil Immersed Transformer , meeting the photovoltaic matching requirements of Combined Photovoltaic Substations . It can be used in combination with High And Low Voltage Switchgear and Electric Power Converter , seamlessly connecting Box Type Substation . It is widely applied in industrial power distribution, high-end parks, photovoltaic power stations, etc., achieving long-term stable power supply and reducing operation and maintenance costs, filling the high-end market gap of resin cast dry-type transformers.
Design features
What the design is built around
Resistant to high temperatures and durable
Using epoxy resin casting technology, it has excellent temperature resistance and insulation performance far exceeding that of ordinary Dry Type Transformers. It can adapt to high-temperature power distribution environments, does not age easily, and the equipment service life is extended by more than 30% compared to traditional dry-type transformers, suitable for industrial high-temperature power distribution scenarios.
Highly adaptable and environmentally friendly
Oil-free design, no pollutant emissions. Compared to Oil Immersed Transformers, there is no need to handle waste oil. It meets the requirements of green development and can seamlessly connect with Box Type Substations and Electric Power Converters, compatible with the photovoltaic power transmission requirements of Combined Photovoltaic Substations, without the need for additional modifications.
Tips
This product is of a resin casting structure. During daily use, avoid sharp objects colliding with the equipment casing to prevent the resin from being damaged and affecting the insulation performance. Before purchasing, confirm the voltage level of the project to avoid mismatch.
Typical specification
Specifications to confirm on the datasheet
| Product type | SC(B)18 Ultra-Low-Loss Dry-Type Transformer |
|---|---|
| Rated capacity | 30-2,500 kVA |
| Voltage class | 10 kV / 20 kV / 35 kV |
| Insulation | Cast epoxy resin, Class F/H |
| Cooling | AN / AF |
| Winding | Copper or aluminium (project-specific) |
| Standards | GB 1094.1, GB/T 6451, IEC 60076-11 |
| Testing | Routine tests, partial discharge and temperature-rise type tests |
The table is a family-level starting point. The approved datasheet fixes the guaranteed values, drawing dimensions and test plan for the specific order.
Typical applications
- Net-zero buildings
- Hyperscale and edge data centres
- Hospitals and laboratories
- Premium commercial projects
- Industrial energy upgrades
Confirm before ordering
- Rated capacity, voltage ratio and tap range
- Impedance, fault level and parallel operation
- Ambient temperature, altitude and enclosure
- Winding material, losses and efficiency class
- Terminations, protection and monitoring
- Tests, inspection, packing and shipping limits
Buyer questions
FAQ for SCB18 Resin Cast Dry-Type Transformer
What is SCB18 Resin Cast Dry-Type Transformer best used for?
What is the typical lead time for SCB18 Resin Cast Dry-Type Transformer?
Which standards and tests apply to dry-type transformers?
Can a dry-type transformer be installed outdoors?
How do I choose between copper and aluminium windings?
Related models
Other configurations in this family
SC(B)18 Ultra-Low-Loss Dry-Type Transformer
SC(B)18 Three-Phase Dry-Type Power Transformer
Currently, there are industry pain points in the medium-voltage power distribution field, such as weak anti-interference ability o…
View model
SC(B)18 Ultra-Low-Loss Dry-Type Transformer
SCB18 Resin-Insulated Dry-Type Power Transformer
In the current medium-voltage power distribution field, traditional Dry Type Transformers often encounter industry challenges such…
View modelProject inquiry
Tell us what the transformer has to do.
Load, voltage class, site conditions, standards and required documents are enough to start. We reply through the inquiry thread.